TY - JOUR
T1 - A new nitrile vinyl linked ultrafast receptor to track cyanide ions
T2 - Utilization on realistic samples and HeLa cell imaging
AU - Kavitha, Venkatachalam
AU - Viswanathamurthi, Periasamy
AU - Haribabu, Jebiti
AU - Echeverria, Cesar
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/7/5
Y1 - 2023/7/5
N2 - A simple D − A (donor − acceptor) type receptor ((2E, 2′E)-3, 3′-(10-octyl-10H-phenothiazine-3,7-diyl)bis(2-(benzo[d]thiazol-2-yl)acrylonitrile)) (PBTA) containing nitrile-vinyl linkage was designed and completely characterized. The receptor PBTA detects CN− ions based on “turn-off” effect with admirable spectral properties. It also owns some of the merits like “naked-eye” color change, ultrafast response (90 s), lowest detection limit (1.25 × 10-10 M) as well as quantitation limit (4.17 × 10-10 M) with the pH range 4–11 which is more suitable pH to make use of the receptor PBTA in physiological medium. The instant detecting ability of the receptor over CN− ions was proved using paper test strip and cotton balls. Further, the utilization of the receptor PBTA was also extended to track CN− ions in realistic samples (water and food samples) and in HeLa cells bioimaging.
AB - A simple D − A (donor − acceptor) type receptor ((2E, 2′E)-3, 3′-(10-octyl-10H-phenothiazine-3,7-diyl)bis(2-(benzo[d]thiazol-2-yl)acrylonitrile)) (PBTA) containing nitrile-vinyl linkage was designed and completely characterized. The receptor PBTA detects CN− ions based on “turn-off” effect with admirable spectral properties. It also owns some of the merits like “naked-eye” color change, ultrafast response (90 s), lowest detection limit (1.25 × 10-10 M) as well as quantitation limit (4.17 × 10-10 M) with the pH range 4–11 which is more suitable pH to make use of the receptor PBTA in physiological medium. The instant detecting ability of the receptor over CN− ions was proved using paper test strip and cotton balls. Further, the utilization of the receptor PBTA was also extended to track CN− ions in realistic samples (water and food samples) and in HeLa cells bioimaging.
KW - Bioimaging
KW - Donor−Acceptor
KW - Realistic samples
KW - Turn-off
KW - Ultrafast response
UR - http://www.scopus.com/inward/record.url?scp=85150013576&partnerID=8YFLogxK
U2 - 10.1016/j.saa.2023.122607
DO - 10.1016/j.saa.2023.122607
M3 - Article
C2 - 36921522
AN - SCOPUS:85150013576
SN - 1386-1425
VL - 295
JO - Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
JF - Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
M1 - 122607
ER -